first_img Click to view the privacy policy. Required fields are indicated by an asterisk (*) Xiao Yang/Lieber Group/Harvard University By Kelly ServickMay. 1, 2019 , 1:45 PM Ultrathin electrical probes (red) integrated seamlessly with neurons (green) in a mouse brain. Country * Afghanistan Aland Islands Albania Algeria Andorra Angola Anguilla Antarctica Antigua and Barbuda Argentina Armenia Aruba Australia Austria Azerbaijan Bahamas Bahrain Bangladesh Barbados Belarus Belgium Belize Benin Bermuda Bhutan Bolivia, Plurinational State of Bonaire, Sint Eustatius and Saba Bosnia and Herzegovina Botswana Bouvet Island Brazil British Indian Ocean Territory Brunei Darussalam Bulgaria Burkina Faso Burundi Cambodia Cameroon Canada Cape Verde Cayman Islands Central African Republic Chad Chile China Christmas Island Cocos (Keeling) Islands Colombia Comoros Congo Congo, the Democratic Republic of the Cook Islands Costa Rica Cote d’Ivoire Croatia Cuba Curaçao Cyprus Czech Republic Denmark Djibouti Dominica Dominican Republic Ecuador Egypt El Salvador Equatorial Guinea Eritrea Estonia Ethiopia Falkland Islands (Malvinas) Faroe Islands Fiji Finland France French Guiana French Polynesia French Southern Territories Gabon Gambia Georgia Germany Ghana Gibraltar Greece Greenland Grenada Guadeloupe Guatemala Guernsey Guinea Guinea-Bissau Guyana Haiti Heard Island and McDonald Islands Holy See (Vatican City State) Honduras Hungary Iceland India Indonesia Iran, Islamic Republic of Iraq Ireland Isle of Man Israel Italy Jamaica Japan Jersey Jordan Kazakhstan Kenya Kiribati Korea, Democratic People’s Republic of Korea, Republic of Kuwait Kyrgyzstan Lao People’s Democratic Republic Latvia Lebanon Lesotho Liberia Libyan Arab Jamahiriya Liechtenstein Lithuania Luxembourg Macao Macedonia, the former Yugoslav Republic of Madagascar Malawi Malaysia Maldives Mali Malta Martinique Mauritania Mauritius Mayotte Mexico Moldova, Republic of Monaco Mongolia Montenegro Montserrat Morocco Mozambique Myanmar Namibia Nauru Nepal Netherlands New Caledonia New Zealand Nicaragua Niger Nigeria Niue Norfolk Island Norway Oman Pakistan Palestine Panama Papua New Guinea Paraguay Peru Philippines Pitcairn Poland Portugal Qatar Reunion Romania Russian Federation Rwanda Saint Barthélemy Saint Helena, Ascension and Tristan da Cunha Saint Kitts and Nevis Saint Lucia Saint Martin (French part) Saint Pierre and Miquelon Saint Vincent and the Grenadines Samoa San Marino Sao Tome and Principe Saudi Arabia Senegal Serbia Seychelles Sierra Leone Singapore Sint Maarten (Dutch part) Slovakia Slovenia Solomon Islands Somalia South Africa South Georgia and the South Sandwich Islands South Sudan Spain Sri Lanka Sudan Suriname Svalbard and Jan Mayen Swaziland Sweden Switzerland Syrian Arab Republic Taiwan Tajikistan Tanzania, United Republic of Thailand Timor-Leste Togo Tokelau Tonga Trinidad and Tobago Tunisia Turkey Turkmenistan Turks and Caicos Islands Tuvalu Uganda Ukraine United Arab Emirates United Kingdom United States Uruguay Uzbekistan Vanuatu Venezuela, Bolivarian Republic of Vietnam Virgin Islands, British Wallis and Futuna Western Sahara Yemen Zambia Zimbabwe V. Altounian/Science Neuronal axon 1 micrometer (μm) Shrinking sensor Several new probes under development are similar in thickness to some axons, neurons’ signal-carrying extensions. A key reason is that the probe provokes an immune reaction in the brain. Its initial plunge into the tissue can tear blood vessels. And even after that damage heals, the probe continues to push and pull on surrounding tissue. In response, nonneuronal cells called glia multiply and form scars that push neurons away from the electrode.Damage also limits the number of electrodes a brain can host, says Cynthia Chestek, a neural engineer at the University of Michigan in Ann Arbor. To get valid data, “We need animals that act normally after they get these implants.” Introduce too many probes and “you’re studying traumatic brain injury.” The constraint on probe number also limits the performance of brain-machine interfaces such as the robotic limb control systems her group is developing; fine motor skills will require more recording channels, Chestek says. So her team is developing much smaller electrodes using rigid carbon fibers roughly 8 micrometers in diameter. These fibers have been shown to record from individual neurons in a rat’s brain for several months with no significant glial scarring or neuron death.Other groups are betting on a different class of material: strong polymers that bend when extremely thin. “The surrounding neurons see the probes, mechanically, as their peers,” says Chong Xie, a neural engineer at the University of Texas in Austin. His group showed in 2017 that 1-micrometer-thick polymer probes produced no scarring in mouse brains over 4 months; recent results extend longevity past a year, he says. Harvard University chemist Charles Lieber has moved even closer to the neuron scale by building electrodes less than a micrometer thick and as flexible as neurons’ axons, or projections. In Nature Materials in February, Lieber’s team showed the probes’ seamless integration in the mouse brain with fluourescence imaging. The team recorded from the same set of cells with no loss of signal or immune response for 3 months.With their ultrafine probes, Lieber’s and Xie’s groups have recorded for months from the rodent hippocampus, a deep structure involved in learning and memory. Conventional electrodes can’t listen in on individual hippocampal neurons for long, Xie says. Researchers typically advance their probes a few micrometers farther every day to capture signals from a new set of cells as their previous targets get damaged or pushed away. By sticking with the same set of neurons for long periods, the new probes could help resolve how the roles of individual neurons evolve in response to animals’ experiences.Because polymer probes are so flexible, driving them into the brain is challenging. Lieber’s team loads its neuronlike strands into a syringe and uses a rigid 400-micrometer-wide needle to deliver the electrodes to precise spots. In a March preprint, Hanson and colleagues at UCSF described a neural “sewing machine,” in which a robotic arm swiftly punctures the brain with a metal needle to push in soft probes. And neural engineer Nicholas Melosh and his team at Stanford University in Palo Alto, California, attach a stiff wire to bundles of their 7-by-1.5-micrometer polymer probes, which peel off as the wire descends into the brain.Last month at a meeting of the Brain Research through Advancing Innovative Neurotechnologies Initiative in Washington, D.C., Melosh presented vivid evidence that smaller probes really are gentler. His group made precise recordings of the minute forces that probes ranging in diameter from 13 to 200 micrometers exerted as they penetrated a living mouse brain. At probe sizes 25 micrometers and below, microscopy showed virtually no tearing of blood vessels. Instead of puncturing capillaries, these smaller wires pushed them aside.That finding is “really, really good news” for ultrasmall electrodes under development, Chestek says.Neuron-scale probes still have to fully demonstrate their longevity and prove they can get good signals in larger animals. But the early signs of safety are encouraging, Chestek says. She points to videos Melosh shared of massive, spreading bleeds from the poke of an 80-micrometer probe. “We used to think 80 microns was small.” Conventional probe 15 μm Email Plastic wrap (for comparison) 12.5 μm For a hair-thin probe penetrating the brain to listen in on neurons’ electrical chatter, finesse is key. It’s easy to rip tissue on the way in. And once in place, a probe can do further damage that muffles the signals it aims to detect. But recent reports describe a generation of finer probes that should prove less damaging. Just a few micrometers thick—comparable to neurons themselves—these tools may soon capture unprecedented long-term recordings from hard-to-reach parts of animal brains. And they may lead to more sophisticated brain-computer interfaces for people.Improved material fabrication techniques have helped labs create the exquisitely fine probes, says neural engineer Timothy Hanson, who developed a system for inserting tiny electrodes while at the University of California, San Francisco (UCSF). And lab tests have shown that brain research using ultrasmall electrodes “can be done, and that it’s worthwhile.”Conventional brain probes are already vanishingly tiny. Stiff electrodes known as Michigan probes, commonly used in neuroscience research, are pointed, ribbonlike shafts that can be as thin as 15 micrometers and are usually 60 micrometers wide or more. In a standard grid known as the Utah array, each spike is roughly 200 micrometers thick at its base. But in the months after either device is implanted, its connection to neurons typically weakens and its signal fades. Example of small polymer probe 1.5 μm Sign up for our daily newsletter Get more great content like this delivered right to you! Country Slender, neuron-size probes aim for better recordings of brain’s electrical chatterlast_img read more